DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-872
MEM-BD (Memory) 
10
Memory Error Detection Test (#87)
This test is a nondestructive test. This test determines if the parity circuitry is 
working. Accordingly, the test determines if parity errors can be detected. The 
parity circuitry is used to detect DRAM memory failures.
Memory Functional Test (#332)
This test is destructive.
This test ensures that every DRAM memory location can be accessed and 
changed independently. Running this test wipes out all data in DRAM memory. 
This test is performed during a 
reset system 4
 or 
reset system 5
. If the test fails 
during a 
reset system
 command, refer to the "Procedure for SPE-Down Mode" 
section of 
, for the recommended 
maintenance strategy.
Table 10-250.
TEST #86 Text Checksum Test 
Error 
Code
Test 
Result
Description/Recommendation 
1029 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT
Refer to “STBY-SPE” for a description of these error codes.
FAIL
The system may or may not continue to operate correctly. The system may 
fail later when some action requires access to the corrupted area of the 
Text.
2. For a 386 system, the flash ROM should be reprogrammed by 
3. the 
upgrade software
 command. The memory card should contain the 
same vintage software that is currently in the system. Refer to the 
"Software Upgrade" section in 
2058
FAIL
(G3iV1.1-286 system only)
.
PASS
The checksum is correct.