DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-891
MET-LINE (MET Line) 
10
MET Circuit and Conference Circuit Test (#57)
The MET Circuit Test checks the amount of reflection from the MET loop around 
circuitry and a Conference Test. The Tone-Clock circuit pack places a 1004-Hz 
tone on a time slot that the port circuit is listening on. A General Purpose Tone 
Detector (GPTD) is connected to another time slot that the same port circuit is 
talking on. The on-board microprocessor places the port in the loop around 
mode and the GPTD measures the level of the reflected signal.
The Conference Test is performed after the Circuit Test. The Conference Circuit 
Test verifies that the NPE is able to listen to several test tones and correctly 
conference them together, and the test is executed in two parts. The first half of 
the test checks the operation of the NPE’s first three conference channels. The 
NPE is put in the loop around mode and instructed to talk on a selected time slot 
and to listen to the 1004-Hz tone using the first three conference channels. The 
signal level and noise level of the conferenced output are then measured using a 
GPTD and checked to verify that they are within an acceptable range.
The second half of the Conference Test checks the operation of the NPE’s 
remaining four conference channels and follows the same procedure as above.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Check to ensure that the board translations are 
correct. Use the 
list config
 command, and resolve 
any problems that are found.
2. If the board was found to be correctly inserted in 
step 1, issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board long
 command. This should 
re-establish the linkage between the internal ID and 
the port. If this is not the case, check to ensure that 
there is a valid board inserted.
Table 10-254.
TEST #56 MET Electronic Power Feed Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page