Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-951
M/T-ANL (Maintenance/Test Analog Port) 
10
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. This error code appears in the Error Log only if the MTB circuit pack has 
been removed since the Error Log was last cleared. Verify that the circuit 
pack has been reinserted.
b. This error indicates a hardware failure on the Analog Port circuitry. 
Replace the Maintenance/Test circuit pack if the alarm is not resolved by 
the command above.
c. This error indicates that call processing records did not agree with 
on-board records for the hook state (on-/off-hook) of the Maintenance/Test 
Analog Port. This error is not service-affecting and no action is required.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
M/T-ANL Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off
 Board
Test to Clear Value
0
1
 (a)
0
Any
Any
Any
test port PCSSpp
1 (b)
41018
none
MINOR
ON
test port PCSSpp l r 3
18 
0
busyout port PCSSpp
WARNING
OFF
release port PCSSpp
257 
Any
NPE Crosstalk test (#9)
MINOR
ON
test port PCSSpp l r 3
513 
Any
Analog Port Sanity Test 
(#963)
MINOR
ON
test port PCSS01 r 2
769 
Any
Analog Port Digital 
Loop Around Test (#13)
MINOR
ON
test port PCSSpp r 3
3840(c)
Any
Hook State Inquiry test 
(#566)