DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Reliability Systems: A Maintenance Aid 
Page 6-15
System Technician Commands for High and Critical Reliability Systems 
6
detect faults and/or lack of faults on those Standby SPE components may 
not have had the opportunity to run. Accordingly, alarms are not raised or 
retired on the components.
If the maintenance activity is scheduled maintenance, and if the 
refresh 
spe-standby
 command is issued before a scheduled translation save is 
performed, the translation save is not done, and the translation data on 
both the Active SPE and Standby SPE tapes or memory cards do not 
reflect changes made since the last translation save.
In general, after a 
refresh spe-standby
 command has been used and the user 
has finished working with the system, the 
test spe-standby long
 command 
should be issued if the 
refresh spe-standby
 command preempted a Standby 
SPE maintenance activity.
Additionally, if the 
refresh spe-standby
 command was used in the time frame in 
which scheduled maintenance with a translation save was to have been 
conducted, the 
save translation
 command should be issued to ensure that the 
current translation data has been written to the Active SPE and Standby SPE 
tapes or Memory Cards. When using the 
refresh spe-standby
 command to 
preempt Standby SPE maintenance activities, it may be necessary to issue the 
refresh spe-standby
 command multiple times to preempt all Standby SPE 
maintenance activity. If the 
refresh spe-standby
 command successfully 
completes five times without the Standby SPE becoming labeled “standby” on 
the status system form, wait 20 minutes. This does not include cases where the 
command completes with the G3MT terminal message “Refresh not successful; 
use ‘display errors’ to check for STBY-SPE errors” or “Cannot interrupt Standby 
SPE while entering maintenance mode; please try later.” Issue the 
refresh 
spe-standby
 command once more.
Commands for TDM Bus Duplication
The 
status system
 command displays the bus on which the control 
channel and tones currently reside (among other information).
The 
test tdm port-network [1 | 2 | 3] [short | long]
 command tests both 
TDM Buses.
The 
set tdm port-network [1 | 2 | 3] a | b [override]
 command moves the 
control channel and dedicated tones to the specified TDM Bus.
The 
busyout tdm port-network [1 | 2 3] bus a | b
 command places the 
specified bus in a maintenance busy state.
The 
release tdm port-network [1 | 2 3] bus a | b
 command places a 
busied-out bus back in service.