Page 10-978
M/T-PKT (Maintenance/Test Packet Bus Port) 
10
M/T-PKT (Maintenance/Test Packet 
Bus Port) 
The Maintenance/Test Packet Bus Port is a port (always Port #4) on the TN771D 
(or later vintage) Maintenance/Test circuit pack, which is required for 
G3iV1.1-286 or G3iV2-386. The Packet Bus port provides the following Packet 
Bus maintenance functions:
Packet Bus fault detection - the ability to detect faults (for example, shorts, 
open leads) on the Packet Bus autonomously (that is, without SPE 
involvement).
Packet Bus reconfiguration - the ability to swap faulty leads with spare 
leads autonomously so that the Packet Bus remains operational. This is 
accomplished by sending messages to all Packet circuit packs [for 
example, ISDN-BRI (TN556)] telling them which spare leads to use on the 
Packet Bus.
Maintenance/Test Packet Bus Port maintenance ensures that these maintenance 
functions are operating correctly. The Maintenance/Test Packet Bus Port is 
alarmed if maintenance determines that the port’s maintenance functions are 
operating incorrectly.
When Maintenance/Test Packet Bus Port maintenance determines that the 
Packet Bus Port is defective, the Packet Bus fault detection and Packet Bus 
reconfiguration functions provided by the port are turned off.
Maintenance/Test Packet Bus Port maintenance interacts with Packet Bus 
maintenance. Therefore, there may be alarms on the Packet Bus when there is a 
fault on the Maintenance/Test Packet Bus Port. Refer to PKT-BUS (Packet Bus) 
Maintenance documentation for further information.
1.
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier designation (A, 
B, C, D, or E); SS is the address of the slot in the carrier where the circuit pack is located (01, 02, 
..., etc.); and pp is the 2-digit port number (for example, 01).
MO Name As 
It Appears in 
Alarm Log
Alarm 
Level
Initial System 
Technician 
Command to Run
1
Full Name of MO
M/T-PKT
Minor
test port PCSSpp l 
Maintenance/Test Packet Bus Port
M/T-PKT
Warning
release port PCSSpp 
Maintenance/Test Packet Bus Port