Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1004
PDMODULE, TDMODULE (Data Module) 
10
Hardware Error Log Entries and Test to Clear 
Values
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
2.
G3iV1.1-286 and G3iV2-386 only.
PDMODULE and TDMODULE Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
40987
None
WARNING
OFF
1 (b)
1 to 20
None
WARNING
OFF
15 (c)
Any
None
18 (d)
0
busyout port 
PCSSpp
WARNING
OFF
release port PCSSpp
257 (e)
40971
None
513
2
0
Data Module Audits 
Test (#17)
WARNING 
(j)
OFF
test port PCSSpp sh r 6
769 (f)
40988
None
WARNING
OFF
1281
Any
Data Module Audits 
Test (#17)
WARNING
OFF
test port PCSSpp sh r 4
1537 (g)
40968
None
WARNING
OFF
1793
Information 
Channel and 
Control Channel 
Loop Around Test 
(#13)
MINOR
ON
test port PCSSpp l r 3
2049
NPE Crosstalk Test 
(#9)
MINOR
ON
test port PCSSpp l r 3
2305 (h)
32770
None
2305 (i)
40967
None
2561
Data Module 
Internal Loop 
Around Test (#175)
WARNING
OFF
test port PCSSpp l r 5
2817 (k)
Link GPP Loop 
(183) Against Links
MAJOR
ON
3841 (l)
NONE