DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1011
PDMODULE, TDMODULE (Data Module) 
10
Information and Control Channel Local Loop 
Test (#13)
This is a set of four tests that check the operation of the information and control 
channels used between the SPE and the Digital Line port circuit.
NOTE:
This is an Internal Loop Around test only and does not check building 
wiring. Use Test #175 for external loop around tests to the data module.
1. The SPE first sends a message to the on-board microprocessor to loop 
around both the information and control channels for the port. Then, the 
primary information channel loop back test is run. The test is performed by 
sending a digital count from the Tone-Clock circuit pack on the primary 
channel time slot and receiving the same digital count with a GPTD. The 
digital count looks like transparent data to the on-board microprocessor.
2500
ABORT
Internal System Error.
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to fail, escalate the problem.
1,2
FAIL
The NPE of the tested port was found to be transmitting 
in Error Log. This causes noisy and unreliable 
connections. Failure Code 1 indicates that the Crosstalk 
Test failed on the primary channel. Failure Code 2 
indicates that the Crosstalk Test failed on the secondary 
channel.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots.
1. To be sure that this is not an intermittent problem, 
repeat this test up to a maximum of 10 times and 
verify that it continues to pass.
2. If complaints still exist, examine the data module, 
connections, and wiring.
Table 10-289.
TEST #9 NPE Crosstalk Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page