DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1062
PI-LINK (Processor Interface Link) 
10
Processor Interface Loop Around Test (#182)
This test is destructive.
The Processor Interface Loop Around Test is an on-board Loop Around Test. The 
test requires that the system technician issue a 
busyout link lnk-no
 command 
before this test is run. This means that the DCS, AUDIX, or ISDN link, for 
example, is torn down. It does not access the TDM Bus at all. When the circuit 
pack is put into local loop around mode, frames are looped internally on the 
circuit pack. If the test fails, the Processor Interface circuit pack reports the 
failure. It is a good check of most of the working hardware on the Processor 
Interface circuit pack.
1.
D = Destructive; ND = Nondestructive
2.
If the PI-LINK under test is BX.25 and if there is an MPDM or an MTDM as part of the link, then 
the PI-LINK test sequence is expanded to include the tests on the data module. These tests are 
run via the PDMODULE or TDMODULE maintenance object. Refer to the PDMODULE 
TDMODULE (Data Module) Maintenance documentation for descriptions and details of these 
tests.
Table 10-305.
TEST #182 Processor Interface Loop Around Test 
Error 
Code
Test 
Result
Description/Recommendation 
1
ABORT
Link was not busied out via system technician.
1. Busyout the link via the 
busyout link lnk-no
 command.
2. Retry the test command. 
2
4
9
ABORT
1. Retry the command at 1-minute intervals a maximum of 5 times.
16
80
84
85
93
94
102
ABORT
Internal system error or possible TN765 PI-BD failure.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, then reset the PI-BD via the 
test interface 
PCS long
 system technician command.
3. If problem still exists, replace the TN765 PI-BD.
Continued on next page