Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1107
PMS-LINK (Property Management System Link) 
10
PMS-LINK (Property Management 
System Link)
Property Management System (PMS) is a stand-alone computer system that a 
hotel/motel-type and a hospital-type environment use for services such as 
reservations, registration, messaging, housekeeping, night audit, billing, and 
inventory. The PMS Link provides a communications channel between DEFINITY 
Generic 1 or Generic 3iV2 and a customer-owned PMSs so that the PMS can 
interrogate the system about the information related to the following features:
Message Waiting Notification
Controlled Restriction
Housekeeping Status
Check-in/Check-out
Room Change/Room Swap
Refer to 
DEFINITY Communications System Generic 3 Feature Description
555-230-204 for details on the PMS feature. The PMS Link is administered to a 
data extension that provides a standard EIA 232C interface to the PMS. A PMS 
can be connected through a data module (PDM, MPDM, DTDM) and a port on 
the TN754 or TN754B Digital Line circuit pack, or through an ADU and a port on 
the TN726 Digital Line circuit pack.
PMS Link Maintenance provides a strategy for maintaining the link between 
DEFINITY Generic 1 and Generic 3iV2 and a PMS device. The strategy includes 
a set of tests for periodic diagnosis, detection of errors during normal operation, 
actions for troubleshooting, and raising alarms for serious problems. PMS Link 
Maintenance uses a "try-and-wait" mechanism for maintaining the PMS Link. If a 
PMS Link is torn down due to an error, PMS Link Maintenance attempts to bring 
up the link immediately. If the trial of "Link Setup" fails, PMS Link Maintenance 
waits for five minutes before the next retry. If the number of retries reaches the 
value of a threshold (12), a Minor alarm is raised for service attention.
PMS Link Maintenance does not cover the maintenance of the elements 
composing the PMS physical link [the external PMS device, Data Module 
(PDM/MPDM/DTDM), and Digital Line Port of TN754 or TN754B Digital Line 
circuit pack, ADU and Data Line Port of TN726 Data Link circuit pack, and Data 
Channels on TN777 Network Control circuit pack]. If PMS Link Maintenance 
cannot restore the PMS Link, then the maintenance tests of these individual 
MO Name As 
It Appears in 
Alarm Log
Alarm 
Level
Initial System 
Technician 
Command to Run
Full Name of MO
PMS-LINK
MINOR
test pms l
PMS Link
PMS-LINK
WARNING
test pms
PMS Link