Maintenance Object Repair Procedures 
Page 10-1116
PMS-PRNT/JNL-PRNT (PMS Printer Link) 
10
PMS-PRNT/JNL-PRNT (PMS Printer 
Link)
NOTE:
PMS-PRNT stands for the pms-log printer. JNL-PRNT stands for the 
wakeup-log printer. Since the maintenance strategy for the both the 
JNL-PRNT and PMS-PRNT MOs is the same, both of these MOs are 
described in this section.
In DEFINITY Generic 1 and Generic 3iV2, there are up to two journal printers. 
They are identified as the wakeup-log printer which is shared between the 
Automatic Wakeup feature and the Emergency Access to Attendant feature to 
print scheduled reports and log of events, and the pms-log printer which is used 
as a backup of the PMS output device to print the audit trail data of all PMS 
transactions executed by the system and the PMS Housekeeping Status Change 
events while the PMS Printer Link is not available. The journal printer link is 
administered to a data extension that provides a standard EIA 232C interface to 
the printer. The printer can be connected through a data module (PDM, MPDM, 
DTDM) and a port on the TN754 or TN754B Digital Line circuit pack, or through 
an ADU and a port on the TN726 Data Line circuit pack.
PMS Printer Link Maintenance provides a strategy in the system for maintaining 
the link between the system and a PMS device (an external Journal Printer 
device). The strategy includes a set of tests for periodic diagnosis, detection of 
errors during normal operation, actions for troubleshooting, and raising alarms 
for serious problems. PMS Printer Link Maintenance uses a try-and-wait 
mechanism for maintaining the PMS Printer Link. If a PMS Printer Link is torn 
down due to an error, PMS Printer Link Maintenance intends to bring the link up 
immediately. If the trial of Link Setup fails, PMS Link Maintenance waits for five 
minutes before the next retry. If the number of retries reaches the value of a 
threshold (15), a Minor alarm is raised for service attention.
PMS Printer Link Maintenance does not cover the maintenance of the elements 
composing the journal printer physical link, for instance, the external printer 
device, Data Module (PDM/MPDM/DTDM) and Digital Line Port of TN754 or 
TN754B Digital Line circuit pack, ADU and Data Line Port of TN726 Data Line 
circuit pack, and Data Channels on TN777 Network Control circuit pack. If PMS 
Printer Link Maintenance cannot restore the PMS Printer Link, then the 
maintenance tests of these individual components of the PMS Link must be 
executed to diagnose faults.
MO Name (in Alarm 
Log)
Alarm Level
Initial Command to Run
Full Name of MO
PMS-PRNT/JNL-PRNT
MINOR
test journal 
pms-log/wakeup-log l
PMS Printer/ Journal Printer
PMS-PRNT/JNL-PRNT
WARNING
test journal 
pms-log/wakeup-log
PMS Printer/ Journal Printer