Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1174
PRI-CDR/SEC-CDR (PRI-CDR Link) 
10
PRI-CDR/SEC-CDR (PRI-CDR Link)
The CDR feature records detailed call information on all incoming and outgoing 
calls on specified trunk groups and sends this information to an CDR output 
device. The two physical links can be administered for connecting external CDR 
output devices to the system. They are identified as the primary CDR (PRI-CDR) 
link and the secondary CDR (SEC-CDR) link. The CDR link can be administered 
to a data extension or the EIA port on the system TN773 Processor circuit pack 
which provides a standard EIA-232C interface. The external CDR output devices 
are:
94A Local Storage Unit (LSU)
TELESEER CDR Unit
Call Accounting System (CAS)
Call Detail Recording Unit (CDRU)
Printer
Host computer
Personal computer (PC)
Customer-provided equipment
Refer to 
DEFINITY Enterprise Communications Server Release 5.4 Administration 
and Feature Description
, for details of the CDR feature.
CDR Link Maintenance provides a strategy for maintaining the link between the 
system and an external CDR output device. The strategy includes a set of tests 
for periodic diagnosis, detection of errors during normal operation, actions for 
troubleshooting, and raising alarms for serious problems. CDR Link Maintenance 
uses a try-and-wait mechanism for maintaining the CDR link. If the CDR link is 
torn down due to an error, CDR Link Maintenance intends to bring the CDR link 
up. If the Link Setup trial fails, CDR Link Maintenance waits 30 seconds before 
the next retry. If the number of retries reaches the value of a threshold (two), a 
Minor alarm is raised for service attention.
The following physical configurations are supported for the CDR link:
From the EIA port of Processor circuit pack to an CDR output device 
through the standard EIA-232C interface.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
Full Name of MO
PRI-CDR/SEC-CDR
MINOR
test cdr-link primary/secondary l
CDR Link
PRI-CDR/SEC-CDR
WARNING
test cdr-link primary/secondary
CDR Link