DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1194
PROCR (TN790 RISC Processor Circuit Pack) 
10
This test verifies that the Processor Instruction and Data Caches are functional. 
Some errors in the caches will simply reduce performance by forcing instructions 
or data to be read from memory more often than would normally be necessary. In 
any case, cache problems are serious and the Processor circuit pack must be 
replaced as soon as possible if they are detected.
Processor Cache Audit (#896)
This nondestructive audit checks the state of the Cache Parity bit maintained by 
the RISC CPU. If this bit is set, there may be problems with either the CPU, the 
Instruction, or Data Cache. An indication of bad cache parity won’t itself mean 
that the system won’t operate, but minor to severe performance degradation may 
be present. For example, a single bad bit in either cache could cause this bit to 
be set. If the faulty word is seldom accessed, the impact will be small. If the bit is 
accessed frequently, there could be serious problems with much, or all, of the 
cache (stuck data bit) with the only direct indication again being the cache parity 
error or cache test error.
Table 10-369.
Test #895 Processor Cache Test 
Error 
Code
Test 
Result
Description/ Recommendation
100
ABORT
The test did not complete within the allowable time period.
1. Retry the command.
1029 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a description of these 
error codes.
 2500
ABORT
Internal system error
1. Retry the command.
FAIL
The Processor cache is not functioning correctly.
1. Replace the Processor circuit pack immediately.
PASS
The cache portion of the Processor circuit pack is operating correctly.
Continued on next page