LED Interpretation 
Page 7-3
Duplication Interface Circuit Pack LEDs 
7
Figure 7-1.
Indicators on Maintenance and Processor Circuit Packs
Duplication Interface Circuit Pack 
LEDs
In a High or Critical Reliability system, there are two Duplication Interface circuit 
packs. One is located in carrier A and one in carrier B of the PPN. Each circuit 
pack has two groups of LEDs. The top three have the traditional function of 
indicating the status of the pack. The LED located at the bottom of the faceplate 
directly beneath the SPE AUTO switch is labeled OVERRIDE. Under normal 
operating conditions, the SPE AUTO switch is in the AUTO (center) position (see 
). This means that the system controls which SPE is active. However, 
there will be times (during maintenance activity, for example) when you, the 
technician, may choose to manually override the SPE selection function. To 
override system selection of the Active processor, move the SPE Select switches 
one at a time on 
both
 Duplication Interface circuit packs from the AUTO position 
ALARM LED (RED)
TEST LED (GREEN)
BUSY LED (AMBER)
MAJOR ALARM LED (RED)
MINOR ALARM LED (RED)
WARNING ALARM LED (AMBER)
ACKNOWLEDGEMENT LED (GREEN)
CONTROL SWITCH
EMERGENCY TRANSFER
ALARMS
MAJOR
MINOR
WRNG
ACK
EMERGENCY
TRANSFER
OFF ON
AUTO
EMERGENCY TRANSFER LED (RED)