Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1211
S-SYN-PT (Speech Synthesis Port) 
10
Notes:
a. An in-line failure of the on-board microprocessor/PSS handshake has 
occurred. Refer to Test #168 for repair procedures.
b. This error type indicates that the circuit pack been removed or has been 
insane for more than 11 minutes. To clear the error, reinsert or replace the 
circuit pack.
c. A transient error that does not cause an alarm can occasionally occur 
during a SPE, TDM BUS, or Tone Clock interchange. Test the port and 
follow the instructions for conference Test (#7).
d. This error is not service-affecting and no action is required.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
NPE 
Crosstalk Test,
 for example, you may also clear errors generated from other tests 
in the testing sequence.
For example, you may also clear errors generated from other tests in the testing 
sequence.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Speech Synthesis PSS Handshake Test 
(#168)
X
X
ND
NPE Crosstalk Test (#6)
X
ND
Conference Circuit Test (#7)
X
ND
Speech Synthesis DTMF Receiver Test 
(#163)
X
ND
Speech Synthesis Memory Test (#166)
X
X
ND
Speech Synthesis DSP Tone Test (#165)
X
X
ND
Speech Synthesis SSD Inquiry Test 
(#167)
X
X
ND
Speech Synthesis DTMF Receiver 
Inquiry Test (#164)
X
X
ND
Speech Synthesis Parameter Update 
Test (#169)
X
X
ND