DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1251
SPE-SELEC (SPE Select Switch) 
10
SPE-SELEC (SPE Select Switch)
The SPE Select Switch MO tracks the state of the SPE Select Switches in a High 
or Critical Reliability system. The switches are located on the Duplication 
Interface circuit pack and can be used to hard-select the active processor in a 
High or Critical Reliability system. Each switch has three positions: SPE-A (the left 
position), AUTO (the middle position), and SPE-B (the right position). To 
hard-select SPE-A, both switches must be in the SPE-A position. To hard-select 
SPE-B, both switches must be in the SPE-B position. Any other combination of 
SPE Select Switches leaves control of the active SPE to the software. Whenever a 
switch is out of the AUTO position, a Warning alarm is raised. If both switches are 
out of the AUTO position for six hours, a Major alarm is raised. Duplication 
Interface circuit pack B reports the state of the SPE-SELEC Switch B to 
Duplication Interface circuit pack A which, in turn, reports the state of 
SPE-SELEC Switch A directly to the system software.
NOTE:
Each switch is a separate MO. If both switches are out of the AUTO 
position, then both switches are alarmed.
It is also possible to get an "init cause" of the SPE-SELEC Switch if SPE B is active 
and power to carrier B is lost. In this case, an SPE switch to SPE A occurs, and 
the "init cause" shows either "SPE-Select Switch" or "SPE-Down."
1.
Where C is the carrier determined by the Port field in the error or alarm log.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
1
Full Name of MO
SPE-SELEC
MAJOR
test duplication-interface 1C sh
SPE Select Switch
SPE-SELEC
WARNING
test duplication-interface 1C sh
SPE Select Switch