Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1308
SVC-SLOT (Service Slot) 
10
SVC-SLOT (Service Slot)
The Service Slot maintenance object is used to detect when an invalid circuit 
pack is inserted into a SERVICE slot. The SERVICE slot is the leftmost slot in the 
J58890BB Port Carrier. It is identified as circuit pack slot location "00" in all 
commands, field entries, and displays used by the system administrator and the 
service technician.
This slot does not provide tip and ring connectivity to the wall field. Therefore, 
only the following circuit pack types are allowed in the slot:
Call Classifier (TN744)
Integrated Announcement (TN750)
Maintenance/Test (TN771C)
Speech Synthesizer (TN725B)
Tone Detector (TN748C)
A MINOR alarm is generated against the Service Slot maintenance object when a 
circuit pack of a type other than that included in the previous list is inserted into a 
SERVICE slot.
The Service Slot maintenance object name is used instead of the maintenance 
object name for the illegal circuit pack to prevent any attempt to assign a port to 
an illegal circuit pack that is physically inserted into the SERVICE slot.
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. This error type indicates that a circuit pack type other than one of the 
following types was inserted into slot 00 (SERVICE slot) of the J58890BB 
port carrier.
MO Name As 
It Appears in 
Alarm Log
Alarm 
Level
Initial System 
Technician 
Command to Run
Full Name of MO
SVC-SLOT
MINOR
none
Service Slot
Service Slot Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
600 (a)
None
MINOR
ON