Page 10-1419
TDM-CLK (TDM Bus Clock) 
10
TDM Bus Clock PPM Inquiry Test (#150)
This test evaluates the quality of the synchronization source for the Tone-Clock 
circuit pack
Table 10-432.
TEST #149 TDM Bus Clock Slip Inquiry Test 
Error 
Code
Test 
Result
Description/ Recommendation
 
ABORT
The system could not allocate the necessary resources for the test.
1001
ABORT
The system could not allocate the necessary resources for the test.
1. Wait 1 minute, and retry the test.
2000
ABORT
Response to the test request was not received within the allowable time 
period.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Any
FAIL
The error code represents the number of timing slips detected on the 
incoming synchronization source since the last slip inquiry was sent to the 
Tone-Clock circuit pack. The incoming synchronization signal can be from 
one of four sources:
1. A Stratum 3 Clock, if that option is administered and the circuit pack 
tested was the active Tone-Clock in the PPN.
2. A DS1 Interface circuit pack, if DS1 Synchronization is administered, 
and associated with the circuit pack tested.
3. The local oscillator on the master Tone-Clock circuit pack, if it is 
providing the system clocking signals.
4. An EXP-INTF circuit pack, if the port network on which the test was 
executed does not contain the current system synchronization 
reference.
The error code is a variable amount ranging from 1 to 255.
1. Small numbers of slips should not result in service degradation. If the 
error code is small (1 or 2), rerun the test. If the error only occurs 
infrequently, it may be ignored.
2. Otherwise, refer to the “Approach to Troubleshooting” section in the 
Synchronization (SYNC) Maintenance section of this manual.
PASS
The Tone-Clock circuit pack does not detect any timing slips. This indicates 
that the incoming synchronization timing source is valid or that the system 
synchronization reference is a Tone-Clock circuit pack. The 
status 
synchronization
 command should be used to verify that the desired 
synchronization reference is providing timing for the system.