DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1429
TIE-DS1 (DS1 Tie Trunk) 
10
l. Error Type 3840
Port Audit and Update Test (#36) failed due to an 
internal system error. Enter 
status trunk
 command and verify the status of 
the trunk. If the trunk is out-of-service, then enter 
release trunk
 command 
to put it back to in-service. Retry the test command. If the test continues to 
abort, then escalate the problem.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the
NPE Crosstalk Test
, for example, you may also clear errors generated from other 
tests in the testing sequence.
NPE Crosstalk Test (#6)
One or more NPEs reside on each circuit pack with a TDM Bus interface. The 
NPE controls port connectivity and gain, and provides conferencing functions on 
a per port basis. The NPE Crosstalk Test verifies that this port’s NPE channel 
talks on the selected time slot and never crosses over to time slots reserved for 
other connections. If the NPE is not working correctly, one-way and noisy 
connections may be observed. This test is usually only part of a port’s Long Test 
Sequence and takes on the order of 20 to 30 seconds to complete.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short 
Test 
Sequence
Long 
Test 
Sequence
D/ND
1
NPE Crosstalk Test (#6)
X
ND
Conference Circuit Test (#7)
X
ND
DS1 Tie Trunk Seizure Test (#136)
X
X
ND
Port Audit and Update Test (#36)
X
X
ND