Справочник Пользователя для Lucent Technologies R5SI
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1502
TONE-PT (Tone Generator)
10
Hardware Error Log Entries and Test to Clear
Values
Values
Notes:
a. A failure in the tone generation facility on the indicated circuit pack has
been detected. Replace the circuit pack. See
in the TONE-BD section.
b. The indicated Tone-Clock circuit pack has been made unavailable via the
busyout tone-clock PC
command. It only applies to systems which have
the High or Critical Reliability Option administered, because only a
standby Tone-Clock circuit pack may be made busy by that command. To
resolve this error, execute the
standby Tone-Clock circuit pack may be made busy by that command. To
resolve this error, execute the
release tone-clock PC
command for the
alarmed circuit pack.
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
replace the circuit pack.
d. The tone generation facility is having problems verifying that tones have
been connected as requested.
e. The tone generation facility may or may not be able to generate tones.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
test description and follow the recommended procedures.
Tone Generator Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test tone-clock PC r 1
1(a)
17664
Tone Generator Audit/
Update Test (#41)
Update Test (#41)
MAJOR/
MINOR
MINOR
ON
test tone-clock PC r 2
18(b)
0
busyout tone-clock PC
WARNING
OFF
release tone-clock PC
130(c)
None
MINOR
ON
test tone-clock PC Sh
257(d,f)
17667
None
MINOR
ON
513(e,f)
17666
Tone Generator Audit/
Update Test (#41)
Update Test (#41)
MINOR
ON
test tone-clock PC r 3
769
Any
Transmission Test (#40)
MAJOR/
MINOR
MINOR
ON
test tone-clock PC r 3
1025
Crosstalk Test (#90)
MAJOR/
MINOR
MINOR
ON
test tone-clock PC l r 2
1281(g)
Any
Tone Generator Audit/
Update Test (#41)
Update Test (#41)
MINOR
ON
test tone-clock PC r 3