DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1506
TONE-PT (Tone Generator) 
10
Tone Generator Transmission Test (#40)
The purpose of this test is to verify that the tone generation hardware on the 
tone-clock circuit pack is capable of generating a subset of system tones and a 
set of test tones. This test does not verify all system tones the tone generator 
produces during normal system operation.
The test is performed in two parts. For the first part, the Tone Generator is told to 
generate the touch-tone digits. The digits are received and checked by a Tone 
Detector touch-tone detector. If any of the digits fail, the test is repeated using a 
touch-tone detector in another Tone Detector circuit pack.
For the second part, the Tone Generator is told to generate call progress tones 
that are detected and identified by a tone detector. These tones are:
440 Hz
2225 Hz
Digital Count 
The tone generator is then told to generate a sequence of test tones whose 
output levels are measured by a tone detector. These tones are:
404 Hz at 0 dB
1004 Hz at -16 dB
1004 Hz at 0 dB
2804 Hz at 0 dB
A Tone Detector general purpose tone detector listens for the tones and 
measures the quality of the tone. If any of the measured values are not within 
limits, the test is repeated using a general purpose tone detector in a different 
Tone Detector circuit pack. If the values are still out of the limits, the test will fail.
For all the failure cases of Test #40, do the following:
1. Check that all Tone Detector circuit packs have the same companding 
mode as that administered for the system. Correct the situation if there is a 
mismatch.
2. Run the long test sequence: 
test tone-clock PC long repeat 1
.
3. If the problem persists, replace the Tone-Clock circuit pack by following 
the steps outlined in the 
 
section.