Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1516
TSC-ADM (Administered Temporary Signaling Connections) 
10
This error may only be affecting service for some DCS customers. Upon 
receipt of this error condition, the switch tears down and re-establishes 
the ADMTSC within 20 minutes.
b. The port field in the error log contains the signaling group number for 
TSC-ADM errors.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the following tables when 
inspecting errors in the system. By clearing error codes associated with the 
TSC 
Heartbeat Inquiry Test,
 for example, you may also clear errors generated
from other tests in the testing sequence.
TSC Heartbeat Inquiry Test(#604)
This test can be invoked by system technician personnel for any ADMTSC 
administered in the switch. The following table indicates the possible error 
conditions that might be encountered when the test is invoked. Most of the error 
conditions do not log an error, but switched services may take some type of 
recovery action in certain instances.
This test sends a USER INFORMATION TSC heartbeat message inquiry across 
an Administered TSC to determine if the far-end can respond to a USER 
INFORMATION TSC heartbeat message.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
TSC Heartbeat Inquiry Test (#604)
ND