DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1542
UDS1-BD (UDS1 Interface Circuit Pack) 
10
ae. Error type 3999 indicates that the circuit pack sent a large number of 
control channel messages to the switch within a short period of time. If 
error type 1538 is also present, then the circuit pack was taken 
out-of-service due to hyperactivity. If error type 1538 is not present, then 
the circuit pack has not been taken out-of-service, but it has generated 
50% of the messages necessary to be considered hyperactive. This may 
be completely normal during heavy traffic periods. However, if this error 
type is logged when the circuit pack is being lightly used, it may indicate a 
problem with the circuit pack or the equipment attached to it.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order they are presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
NPE 
Connection Audit Test,
 for example, you may also clear errors generated from 
other tests in the testing sequence.
Table 10-455.
System Technician-Demanded Tests: Descriptions and Error Codes
Order of Investigation
Short 
Test 
Sequence
Long Test 
Sequence
Reset Board 
Sequence
test ds1-loop 
Command
 D/ND
1
NPE Connection Audit 
Test (#50)
X
ND
Control Channel Loop 
Test (#52)
X
ND
Loss of Signal Alarm 
Inquiry Test (#138)
X
X
ND
Blue Alarm Inquiry Test 
(#139)
X
X
ND
Red Alarm Inquiry Test 
(#140)
X
X
ND
Yellow Alarm Inquiry 
Test (#141)
X
X
ND
Major Alarm Inquiry 
Test (#142)
X
X
ND
Minor Alarm Inquiry 
Test (#143)
X
X
ND
Continued on next page