Maintenance Object Repair Procedures
Page 10-1572
UDS1-BD (UDS1 Interface Circuit Pack)
10
Yellow Alarm Inquiry Test (#141)
Receiving a Yellow alarm from remote DS1 endpoint indicates that the remote
DS1 endpoint has an out-of-frame condition. The Yellow Alarm Inquiry Test is
used to determine whether the remote DS1 endpoint is transmitting a Yellow
alarm. The UDS1 Interface circuit pack takes 500 msec to recognize and report a
Yellow alarm and 500 msec to recognize and report that a Yellow alarm condition
is cleared.
DS1 endpoint has an out-of-frame condition. The Yellow Alarm Inquiry Test is
used to determine whether the remote DS1 endpoint is transmitting a Yellow
alarm. The UDS1 Interface circuit pack takes 500 msec to recognize and report a
Yellow alarm and 500 msec to recognize and report that a Yellow alarm condition
is cleared.
When the UDS1 Interface circuit pack detects a Yellow alarm from the remote
DS1 endpoint, it will send a YELLOW-ALARM uplink message to the
maintenance software. After the maintenance software receives the
YELLOW-ALARM message, the Yellow Alarm Inquiry Test is run to confirm the
Yellow alarm. Once the Yellow alarm is confirmed, the maintenance software
DS1 endpoint, it will send a YELLOW-ALARM uplink message to the
maintenance software. After the maintenance software receives the
YELLOW-ALARM message, the Yellow Alarm Inquiry Test is run to confirm the
Yellow alarm. Once the Yellow alarm is confirmed, the maintenance software
PASS
No Red alarm is detected on the UDS1 Interface circuit
pack.
pack.
0
NO
BOARD
BOARD
The test could not relate the internal ID to the port (no
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Ensure that the board translations are correct.
Execute the
add ds1 PCSS
command to administer
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly,
check the error log to determine whether the board
is hyperactive. If this is the case, the board is shut
down. Reseating the board will re-initialize the
board.
is hyperactive. If this is the case, the board is shut
down. Reseating the board will re-initialize the
board.
3. If the board was found to be correctly inserted in
step 1, then issue the
busyout board
command.
4. Issue the
reset board
command.
5. Issue the
release busy board
command.
6. Issue the
test board long
command.
This should re-establish the linkage between the internal
ID and the port.
ID and the port.
Table 10-462.
TEST #140 Red Alarm Inquiry Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page