DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-33
busyout sp-link 
8
Output
For the following output example, the command "busyout pri-endpoint 22501" 
was entered. Assume that the PRI endpoint ports for extension 22501 are in 
cabinet 1, carrier B, slot 20, circuit 1 to 6.
Feature Interactions
If there is an active call on the specified PRI endpoint, the busyout command will 
cause the call to drop. This command is destructive.
Once the PRI endpoint is in the maintenance busy (system technician busy) 
state, all call attempts from the far-end PRI terminal adapter will be denied with a 
cause value 17 (User Busy).
busyout sp-link
This command will busyout the system printer link.
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance 
object that is being busied out.
Maintenance Name
The type of maintenance object that is being busied out. The 
name for PRI endpoint port is "PE-BCHL."
Alt. Name
The alternate way of identifying the maintenance object. This field 
contains the extension number of the PRI endpoint.
Result
An indicator as to whether the object is successfully busied out. 
The possible values are: PASS, FAIL or ABORT.
Error Code
A system-generated number that tells why the busyout failed or 
aborted. A detailed list of the codes can be in the 
"Busyout/Release Error Codes" section of this chapter.
 
 busyout pri-endpoint 22501                         SPE A
                             COMMAND RESULTS
   Port    Maintenance Name  Alt. Name   Result       Error Code
   01B2001   PE-BCHL          22501       PASS
   01B2002   PE-BCHL          22501       PASS
   01B2003   PE-BCHL          22501       PASS
   01B2004   PE-BCHL          22501       PASS
   01B2005   PE-BCHL          22501       PASS
   01B2006   PE-BCHL          22501       PASS
 Command Successfully Completed