Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1578
UDS1-BD (UDS1 Interface Circuit Pack) 
10
Major Alarm Inquiry Test (#142)
The Major alarm raised by a UDS1 Interface circuit pack indicates that the 
average bit error rate on the DS1 facility is greater than 1/1000. The Major Alarm 
Inquiry Test is used to determine that the received DS1 bit error rate is greater 
than 1/1000. The UDS1 Interface circuit pack takes 10 seconds to recognize and 
report a Major alarm and 10 seconds to recognize and report that a Major alarm 
condition is cleared.
When the UDS1 Interface circuit pack detects a Major alarm, it will send a 
MAJOR-ALARM message to the maintenance software. (32-channel interfaces 
send a YELLOW alarm to the far end). After the maintenance software receives a 
MAJOR-ALARM message, the Major Alarm Inquiry Test is initiated to confirm the 
 
PASS
Neither a Yellow alarm nor a Remote Multiframe Alarm 
nor a F5 state alarm is being received from the remote 
DS1 endpoint.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Ensure that the board translations are correct. 
Execute the 
add ds1 PCSS
 command to administer 
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly, 
check the error log to determine whether the board 
is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the 
board.
3. If the board was found to be correctly inserted in 
step 1, then issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the linkage between the internal 
ID and the port.
Table 10-463.
TEST #141 Yellow Alarm Inquiry Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page