Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1591
UDS1-BD (UDS1 Interface Circuit Pack) 
10
Misframe Alarm Inquiry Test (#145)
Misframe Alarm indicates that framing bits observed on a UDS1 Interface circuit 
pack are in error. The Misframe Alarm Inquiry Test queries the total number of 
misframes that have occurred on a DS1 Interface circuit pack since the last 
inquiry.
When the DS1 Interface circuit pack detects a misframe error, it will increase its 
misframe counter by 1. If the counter reaches a specified threshold (i.e.- 17), a 
MISFRAME-COUNT message is automatically sent to the switch maintenance 
software. After the maintenance software receives the MISFRAME-COUNT 
message, the Misframe Alarm Inquiry Test is initiated to collect the misframe 
counts from the UDS1 Interface circuit pack.
When the threshold of misframes is reached, if the UDS1 Interface circuit pack is 
supplying the system synchronization source, then a switching synchronization 
source message is sent to the TDM Bus Clock. See TDM-BUS (TDM Bus) 
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Ensure that the board translations are correct. 
Execute the 
add ds1 PCSS
 command to administer 
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly, 
check the error log to determine whether the board 
is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the 
board.
3. If the board was found to be correctly inserted in 
step 1, then issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the linkage between the internal 
ID and the port.
Table 10-466.
TEST #144 Slip Alarm Inquiry Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page