Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1642
VC-DSPPT 
10
VC DSP Port Local TDM Loopback Test (#1104)
This test is destructive.
This test verifies the connectivity of a VC DSP Port across the TDM bus. It aborts 
if calls associated with the port are in progress. Failure of this test indicates an 
on-board fault associated with the port hardware on the circuit pack. The 
Loopback Test runs the following tests: 
1. A Looparound test across the TDM bus.
2. A conference Circuit Test.
The tests are run in the above order; if one test fails, an error code is returned 
and the remaining tests in the sequence are not executed.
Table 10-480.
TEST #1103 VC DSP Port NPE Crosstalk Test
Error 
Code
Test 
Result
Description/ Recommendation
1000 
1001
ABORT
System resources required to run this test are not available. The port may 
be busy with a valid call.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2012
ABORT
Internal system error
2100
ABORT
Could not allocate the necessary resources to run this test. 
1. Retry the command at 1-minute intervals a maximum of 5 times.
0-3
FAIL
The NPE of the tested port was transmitting in error. This causes noisy and 
unreliable connections.
1. Replace circuit pack.
PASS
The port is correctly using its allocated time slots.
1. To be sure that this is not an intermittent problem, repeat this test a 
maximum of 10 times to make sure that it continues to pass.
2. If complaints still persist, examine the station, connections, and wiring.
Continued on next page