Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-43
busyout tone-clock 
8
Feature Interactions
If a bus is busied out, no calls will be torn down. However, no new calls will be set 
up on the busied out bus.
Dedicated tone time slots must be moved to another bus (the other half of the 
duplicated bus) before a busyout of a particular bus will be allowed.
busyout tone-clock
This command will busyout a tone/clock circuit pack.
Synopsis
busyout tone-clock location
Permissions
The following default logins may execute this command: system technician, 
inads, init.
Examples
busyout tone-clock 01c 
busyout tone-clock 03d
Description
The busyout tone-clock command will put the specified tone/clock in a 
maintenance busy state. There will be no periodic or scheduled tests performed 
on the busied out object until it is released. When the object is maintenance busy 
then the object is removed from active service on the switch (i.e., no call 
processing activity may include the busied object). Warning alarms are 
generated (error type 18) on each tone clock circuit pack busied out, so that 
INADS can access the state of the objects. The release tone-clock command will 
return the specified tone/clock to operation.
Defaults
The cabinet number will default to 1 (one).