DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-67
change system-parameters maintenance 
8
Modem Connection
On page 3 of the example forms shown below, there are 11 fields that are hidden 
when the “Modem Connection?” field is set to internal. In this example the 
“Modem Connection” field is set to “external” and these additional 11 fields are 
visible.
The first 2 fields on page 3 help setup the data format for the serial data from the 
switch to the modem. The field names are, “Data Bits:”, and “Parity?”. There are 
only two valid combinations for these 2 fields:
Data Bits = 8, Parity = None
Data Bits = 7, Parity =(odd, even, mark, or space)
 The remaining fields are listed below:
SPE Optional 
Boards:
These fields indicate whether a Disk circuit pack is present in the 
system, and which Packet Interface slots are administered. If a Packet 
Interface circuit pack is physically present, the corresponding Packet 
Interface field is set to y when the system boots, and no change to that 
field is allowed. If the system is equipped with duplicated SPEs, a 
Packet Interface field is set to y when either SPE carrier contains a 
Packet Interface circuit pack in the corresponding position. If a Packet 
Interface circuit pack is not present, then the value for the Packet 
Interface field is read from translation data stored on disk or tape. If the 
field is set to n, a  Packet Interface circuit pack may be administered by 
changing the corresponding Packet Interface field to y.
Modem Connection
The only valid entries for this field are “internal” or “external”. 
The default is set to internal. (internal)
Modem Name
This field is 20 characters long and will permit alpha-numeric 
characters to provide a unique qualifier for a given modem. The 
field is called “Modem Name: ”. ( )
RTS/CTS Enabled
This field will inform the modem that communication with the 
data source UART will be driven with RTS/CTS flow control. This 
field is 6 characters long with a default of “\Q3”. This field is 
case in-sensitive; however, the default will be in upper case. 
(\Q3)