DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Architecture 
Page 1-3
Protocols 
1
Background tests are performed by software maintenance, usually on an 
hourly basis. These tests are nondestructive and can be run during high 
traffic periods without interfering with calls.
Scheduled
Background tests performed by software maintenance, usually on a daily 
basis, are generally more thorough than periodic testing. The tests are 
considered destructive and are run only during off-hours so as not to 
interfere with calls.
Fixed interval
Background tests performed by software maintenance at regular time 
intervals (these intervals cannot be administered). These tests run 
concurrently with periodic maintenance. The following table lists the MOs 
that run fixed interval testing.
Demand tests are also run by the system when it detects a need or by 
maintenance personnel in trouble-clearing activities. Demand tests include 
periodic tests plus other tests required only when trouble occurs. Some 
nonperiodic demand tests may disrupt system operation. In this book, 
destructive (service-disrupting) tests are identified in boldface type.
Maintenance personnel can use the management terminal to initiate the same 
tests that the system initiates. The terminal screen displays the test results.
Protocols
This section describes the protocols handled by the system and the points where 
these protocols change. 
 is a pictorial guide through data- 
transmission state changes. 
 illustrates the flow of data from DTE 
equipment, like a terminal or host, through DCE equipment, like a modem or data 
module, into a communications port on the system. The data flow is shown by 
solid lines. Below these lines are the protocols used at particular points in the 
data stream.
Not shown in the 
 is the treatment of D-channels in ISDN-PRI and 
ISDN-BRI transmissions. PRI and BRI D-channels transport information elements 
Maintenance Object
Interval 
(minutes)
POWER
60
SPE-SELEC
60
STBY-SPE
120
TDM-BUS
10
TONE-PT
10