Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-92
disable synchronization-switch 
8
Output
The command returns one of the following messages:
1. If the board specifier is not valid:
Board invalid
2. If no entries can be disabled in the Suspend Alarm Origination table:
Entry not found; no entries disabled
Feature Interactions
None.
disable synchronization-switch
This command disables automatic clock switching.
Synopsis
disable synchronization-switch
Permissions
The following default logins may execute this command: system technician, 
inads, init.
Examples
disable synchronization-switch
Description
The disable synchronization command stops the automatic clock switching 
capability of the maintenance subsystem. Clock refers to the oscillator on a 
tone/clock or DS1 interface.
The synchronization subsystem provides error free digital communication 
between the switch and other PBXs, COs, or customer premise equipment. The 
subsystem is made up of system components involved in synchronization: TDM 
bus clock, DS1 trunk board, maintenance and administration software resident in 