DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-98
display alarms 
8
Parameters
Backward Paging of the Alarm/Error Log
The user can display the next and previous pages of the alarm/error log. When 
the user executes the 
display alarm/error
 command to view the alarm/error log. 
If more than one page of alarms/errors is stored by the system, the user may use 
the 
NEXT PAGE key
 or the 
PREV PAGE
 key (513 or 715 terminals only use 
F8 
or
F7
 for 
all other terminals) to toggle between pages (up to a maximum of two pages). If 
the system has storied one or less than one page of alarms/errors the command 
will display the alarms/errors and echo 
Command successfully completed
 and 
exit. Help messages/Key actions:
Next Page
The command will display the next page. If the user is not viewing 
the first page of alarms/errors, is not viewing a page as a result of depressing the 
Prev Page
 key, and there are more entries to display, the help message will be:
press CANCEL to abort, NEXT PAGE to complete, or PREV PAGE for previous 
page.
Prev Page
Press previous page key to return to the previous page. The system 
will display the help message:
 
press CANCEL to abort or NEXT PAGE for next page
 If the user is not viewing the 
first page of alarms/errors, is not currently viewing a page as a result of pressing 
the 
prev Page
 key, and there are no remaining entries to display, the help 
message will be:
press CANCEL to abort, NEXT PAGE to complete, or PREV PAGE for previous 
page.
Help Messages
If the technician presses 
HELP
 after entering "display alarms" the following 
message will be displayed:
      [’print’ or ’schedule’]
print
This will cause the report to be printed if a printer is linked to the SAT.
schedule
When the "schedule" option is specified, the command is validated 
and then a scheduling form is displayed to allow the technician to 
schedule execution of the command. The command is then placed in 
the command queue and is executed at the specified time. The 
information displayed by the command is sent to the system printer 
instead of the screen. Refer to the Report Scheduler and System 
Printer feature specification [4] for more details.
There are no parameters entered on the command line, parameters 
are selected on the hardware alarm report form instead.