DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-164
enable suspend-alm-orig 
8
On the command line, specify a time-out duration between one and 72 hours. 
The “off-board-only” keyword is optional; if the keyword is not specified, the entry 
suspends Alarm Origination for both on-and off-board alarms. Each enable 
command becomes a new entry or replaces an existing entry in the Suspend 
Alarm Origination table. A new entry that matches both the physical location and 
off-only/on- and off-board specifications of an active entry replaces the active 
entry in the Suspend Alarm Origination table.
This command may be particularly useful for improving control over situations 
such as the following:
Improved control over customer requests. For example, to suspend 
off-board DS1 alarms temporarily for customers that periodically 
disconnect DS1 trunks for testing or other business related purposes.
Improved control over external (non-Lucent) problems. For example, to 
suspend off-board DS1 alarms before a customer resolves facility 
problems (such as working with the vendor of a T1 trunk that has 
developed an off-board condition).
Improved control over internal (Lucent) problems that we cannot resolve 
right away. For example, to suspend Alarm Origination for a bad circuit 
pack detected late Friday night and we cannot dispatch personnel to 
replace the circuit pack until well into Monday.
Improved control over chronic problems that we have not yet found a 
solution to.
NOTE:
Also see other Suspend Alarm Origination related commands, including 
“disable suspend-alm-orig” and “list suspend-alm-orig”.
Defaults
This command enables Suspend Alarm Origination for both on- and off-board 
alarms if the “off-board-only” keyword is not specified.
Parameter
Help Messages
Enter board or port location,
[‘off-board-only’], expires-in-hrs(1-72)
board or port 
location
This parameter specifies the physical location of the hardware 
component for suspending Alarm Origination.
off-board-only
This option enables Suspend Alarm Origination for off-board alarms 
only.
expires-in-hrs
This parameter specifies the time-out duration for a Suspend Alarm 
Origination entry. Expired entries are removed automatically.