DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-195
list measurements 
8
 Cannot get time from system clock
Output
The following field descriptions pertain to the summary reports accessed by the 
"list measurements ds1 summary" command.
Counted 
Since:
The start time and date when the associated measurement counters 
were cleared or the DS1 circuit pack was administered.
Number of 
Seconds 
Elapsed Into 
Current 
15-min 
Interval:
The number of seconds from the beginning of the current 15-minute 
interval. This field has a value from 0 to 900.
Total of Valid 
15-min 
Intervals in 
Past 24-hr 
Period:
The total number of 15-minute intervals in the past 24-hour period that 
contain valid data. This field has a value from 0 to 96.
Category
The four categories correspond to four measurement error counters. 
The four categories are "Errored Seconds," "Bursty Err Secs," "Severely 
Err Secs," and "Failed Seconds". The meanings of each category 
follow:
The value of the errored seconds counter for the specified 
15-minute interval. This field has a value from 0 to 900 or N/A if the 
data for the 15-minute interval is invalid.
The value of the bursty errored seconds counter for the specified 
15-minute interval. This field has a value from 0 to 900 or N/A if the 
data for the 15-minute interval is invalid.
The value of the severely errored seconds counter for the specified 
15-minute interval. This field has a value from 0 to 900 or N/A if the 
data for the 15-minute interval is invalid.
The value of the failed seconds counter for the specified 15-minute 
interval. This field has a value from 0 to 900 or N/A if the data for 
the 15-minute interval is invalid.