DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-269
refresh spe-standby 
8
Synopsis
refresh spe-standby
Permissions
The following default logins may execute this command: system technician, 
inads, init.
Examples
refresh spe-standby
Description
The refresh spe-standby command is used to immediately put the Standby SPE 
into Standby Mode. The command conducts the same activities regardless of 
whether the Standby SPE is already in Standby or Maintenance Mode. When this 
command is issued, any Standby SPE maintenance activity that is currently is 
progress is preempted, the Standby SPE Processor is held reset, and the 
Standby SPE’s DRAM memory is refreshed (that is, all of Active SPE DRAM 
memory is shadowed to the Standby SPE memory). The refresh is necessary 
because while the Standby SPE is in Maintenance Mode, memory shadowing is 
disabled. When the Standby SPE is returned to Standby Mode, its memory must 
be brought up-to-date with Active SPE memory.
Because of its power to preempt Standby SPE maintenance activities, the refresh 
spe-standby command should be used judiciously. If the Standby SPE is in 
Maintenance Mode when the refresh spe-standby command is issued, the 
maintenance activity that is being conducted by the Standby SPE is immediately 
terminated with the following potential side-effects:
Testing of the Standby SPE components that are the target of the 
maintenance activity may not have completed. Depending on the 
maintenance activity and the point at which it is terminated, tests that 
detect faults and/or lack of faults on those Standby SPE components may 
not have had the opportunity to run. Accordingly, alarms are not raised or 
retired on the components.
If the maintenance activity is scheduled and if the refresh spe-standby 
command is issued before a scheduled translation save is performed, the 
translation save is not done and the translations data on the Active and 
Standby SPE mass storage devices do not reflect the changes made 
since the last translation save.
Defaults
No defaults.