Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-393
status bri-port 
8
Output
Port:
This field specifies the physical address of the ISDN-BRI port.
Service State:
This field specifies whether the ISDN-BRI port is "in-service" or 
"out-of-service."
Maintenance Busy?:
This field specifies whether there is any maintenance testing 
being performed upon the ISDN-BRI port ("yes" or "no").
Layer 1 State:
This field contains the layer 1 (physical) state of the BRI on the 
port. Valid states are "activated," "pend-activation," and 
"deactivated."
The "activated" state means layer 1 frames are being passed 
between the port and BRI endpoints.
The "pend-activation" state specifies that the port has been 
placed in-service, the layer 1 interface device has been 
turned on, layer 1 frames are being sent to the BRI endpoints 
connected to this port, but the BRI endpoints are not 
responding.
The "deactivated" state means that the layer 1 interface 
device on the BRI has been turned off due to the port going 
out-of-service.
TEI Value
The Terminal Endpoint Identifier(TEI) is a layer 2 addressing 
parameter used by the switch to pass information over the 
point-to-point signaling link to and from BRI endpoints. Each 
point-to-point signaling link has a TEI associated with it. This field 
displays the value of this addressing parameter. This value is in 
the range from 0 to 127.