status data-module 
8
Output
For the following output example, the command that was entered is "status 
data-module 301".
Feature Interactions
None.
Data Ext/Sta Ext 
for Stn DM
The data module extension number. The DTDM is an exception: the 
connected station extension is shown.
Port/Channel 
Number
The port location of the data module (cabinet-carrier-slot-circuit). If 
the data module specified is a data channel, the channel number 
will be shown instead.
Service State
This entry displays the status of the data module; valid states are:
— In-service/idle
— The data module is present but not in use.
— In-service/active
— The data module is present and is in use.
— Out-of-service
— The data module has been removed from service
— Disconnected
— The data module no longer appears to be present
CF Destination Ext
This entry displays the call forwarding destination, if any, of the 
station.
Maintenance 
Busy?
Whether maintenance is testing the object, "yes" or "no".
Connected Ports
Port locations to which the data module is connected 
(cabinet-carrier-slot-circuit).
 
 status data-module 301
                           DATA-MODULE STATUS
 Data Ext/Stn Ext for Stn DM: 301        Service State: out-of-service
         Port/Channel Number: 01C1103    Maintenance Busy? no
          CF Destination Ext: