Справочник Пользователя для Lucent Technologies R5SI
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-505
status station
8
Permissions
The following default logins may execute this command: system technician,
inads, cust, init, browse.
inads, cust, init, browse.
Examples
status station 10020
status station 83277
status station 83277 print
status station 83277
status station 83277 print
Description
The status station command displays internal software state information for
diagnosis. This command can help locate facilities to which the station is
communicating.
diagnosis. This command can help locate facilities to which the station is
communicating.
Defaults
No defaults.
Parameters
Help Messages
If the system technician presses
HELP
after entering "status station", the following
message will be displayed:
Enter assigned extension, [’print’]
Error Messages
If the extension format is incorrect, the following message will be displayed:
Extension invalid
If the extension is not administered, the following message will be displayed:
Extension not assigned
If the object associated with the extension is not a station or an attendant
console, the following message will be displayed:
console, the following message will be displayed:
Extension exists but assigned to a different object
extension
The extension of the station to be displayed. The number of digits in an
extension is determined by a dial-plan.
extension is determined by a dial-plan.
print
This will cause the report to be printed if a printer is linked to the SAT.