Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-525
status trunk 
8
If the trunk identifier is not in the valid range, the following error message is 
displayed:
Trunk or trunk group invalid
If the trunk group is not administered or has no members, the following message 
is displayed:
Group not assigned, or group assigned 
but with no member
If the trunk group member is not administered, the following message is 
displayed:
Group member not assigned
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message is displayed:
Command resources busy; 
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message is displayed:
All maintenance resources busy; try again later
MEMBER Output
The following is output when a user enters a trunk group and member:
Trunk Group/Member
The trunk group number and group member number. Valid 
identifiers are 1-99/1-99.
Port
The port location (cabinet-carrier-slot-circuit) of the trunk.
Signaling Group ID
If the trunk is of type ISDN, then this field contains the number of 
the ISDN Signaling Group to which this group belongs. 
Otherwise, this field is blank.
Connected Ports
Port locations (cabinet-carrier-slot-circuit) connected to the 
trunk.