Maintenance Commands and Trouble-Clearing Aids 
Page 8-555
test card-mem 
8
The tests in the sequence can verify the sanity of the memory card device, the 
basic read/erase/write operations to the memory card, the integrity of the 
translation data stored in the memory card, the function of 12 volt power supply 
in TN777B NETCON circuit pack used for memory card erase/write operations, 
the translation capacity of the memory card, and the consistency of data stored 
in both memory cards in a High or Critical Reliability System. This command can 
help system technician to trouble-shoot the hardware errors related to 
maintenance objects such as "CARD-MEM", "12V-PWR", CAP-MEM, and 
"FL-DATA" logged in the system hardware error log. The details of test results 
and the repair procedures for recovery are described in Maintenance Service 
Document associated with each maintenance object.
If the switch is a simplex system, then the "Flash Data Consistency Test" is not 
executed.
Defaults
The defaults for this test command are "short" with a repeat number of "1". The 
location of carrier where the memory card resides must be specified in the 