Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-595
test inads-link 
8
System Interaction
The performance of "test hardware-group" is affected by call processing traffic, 
administration activity, choice of the ’short’ or ’long’ option, whether the ’all-ports’ 
option was chosen, whether the ’spe-interchange’ option was chosen, and other 
demand maintenance activity.
Scheduled and Periodic maintenance
When a "test hardware-group" command is entered, all activity related to 
scheduled background maintenance, periodic background maintenance, and 
data audits is suspended for the duration of the execution of the "test 
hardware-group" command. When a "test hardware-group" command is 
canceled or when the "test hardware-group" command completes, all suspended 
periodic, scheduled, and data audits background maintenance activity will be 
restarted where it left off.
test inads-link
This command will perform hardware diagnostic tests from the inads port that is 
accessible through the maintenance board to an OSS telephone number.
Synopsis
test inads-link [1 | 2]
Permissions
The following default logins may execute this command: system technician, 
inads, init, nms.
Examples
test inads-link
test inads-link 1
test inads-link 2
Description
The test inads-link command attempts to make a call over the inads port on the 
maintenance board to verify the INADS alarm notification process. By default, the 
link to the first OSS telephone number is tested. If there is an alarm pending to be 
reported or the call is in progress or up, then the test will be aborted. If the alarm 
origination to the OSS telephone number to be tested is disabled, the test 
generates an informative error and the test continues. The test will wait 2 minutes 
before executing to allow the remote maintenance technician to logoff freeing the