DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-617
test memory 
8
Description
This command performs hardware diagnostic tests on any one memory circuit 
packs or on all memory circuit packs in the technician specified carrier. Neither 
the short nor the long test is destructive when testing memory.
Defaults
The cabinet default is always cabinet 1. For SPE simplex systems, the default 
carrier is the "a" carrier. For SPE duplex systems, there is no default carrier. The 
defaults for the remaining parameters are short with a repeat of 1.
Parameters
Help Messages
If the system technician presses 
HELP
 after entering "test memory" on a simplex 
SPE system the following message will be displayed:
Enter [cabinet(1)];carrier(A), 
location
The location designates the physical position of the desired memory 
circuit pack. The location consists of a cabinet number and carrier 
letter. The cabinet number is always optional and must be a "1" or a 
"01" if entered. The carrier must be either "a" or "b" for SPE duplex 
systems. For SPE simplex systems, the carrier must be "a" if entered.
short
This will cause the command to execute a series of nondestructive 
diagnostic tests.
long
This will execute a more comprehensive and longer version of the 
diagnostic tests. The long version does not include any destructive 
tests for this command.
repeat number
The "number" specifies how many times each test in the sequence is 
to be repeated. "Number" may be any integer between 1 and 100.
clear
This option causes the test sequence (short or long) to repeat until the 
alarm (if one exists against the maintenance object) is cleared or a 
single test in the sequence fails. If no alarms are registered against the 
maintenance object then the test sequence will be exercised only 
once. The long clear option forces a clear of all alarms if no errors are 
encountered during testing. The short clear option only clears alarms 
pertinent to tests in the short sequence.
schedule
When the "schedule" option is specified, the command is validated 
and then a scheduling form is displayed to allow the technician to 
schedule execution of the command. The command is then placed in 
the command queue and is executed at the specified time. The 
information displayed by the command is sent to the system printer 
instead of the screen. Refer to the Report Scheduler and System 
Printer feature specification [1] for more details.