DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-639
test pms-link 
8
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
All maintenance resources busy; try again later
Output
The responses will be displayed on a test-by-test basis with one line of data 
displayed for each test result.
For the following example, the command entered was "test pms-link l".
Feature Interactions
The maintenance of a particular component on a link may interfere with the 
maintenance of the link itself. Maintenance can put a link component in a busy 
state causing link set-up to fail. Frequent attempts at re-setup of a link may delay 
the recovery of a faulty component, due to the maintenance test of a component 
only taking place when the component is idle. Therefore, the technician needs to 
be able to disable the attempted re-setup of a link. The busyout command is 
used to do this, and causes the link to be torn down. If the link is already down, 
the busyout command stops periodic re-setup tries on the link.
Port
With this object the port field is blank.
Maintenance Name
The type of MO that is being tested (always PMS-LINK).
Alt. Name
Not applicable.
Test No
The actual test that is being executed.
Result
The result of the individual test -"PASS," "ABORT," "FAIL," "NO 
BOARD," "DISABLED," "EXTRA BD."
Error Code
A system-generated number that tells why the release failed or 
aborted. A detailed list of the codes according to "Test No." is 
provided for each MO.
 
 test pms-link long
                               TEST RESULTS
   Port    Maintenance Name  Alt. Name Test No. Result       Error Code
           PMS-LINK                    214      PASS
 Command Successfully Completed