Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-653
test shadow-link 
8
If the standby SPE is busy with another task, then the following message is 
displayed
Standby SPE busy with another task; 
for information use "status system 1"
If the standby SPE is not available when this command is executed, then the 
following message is displayed:
Standby SPE not available; 
for information use "status system 1"
Output
The responses will be displayed on a test-by-test basis with one line of data 
displayed for each test result.
For the following output example, assume that the command that was entered 
was "test shadow-link"
Feature Interactions
None.
Port
The port address will always be blank for this command.
Maintenance Name
The maintenance name will always be SHDW-LNK for this 
command.
Alt. Name
Not applicable.
Test No
The test number will always be 318 for this command.
Result
The result of the individual test -"PASS," "ABORT," "FAIL," 
"DISABLED,".
Error Code
A system-generated number that tells why the test failed or 
aborted. A detailed list of the codes according to "Test No." is 
provided for each MO.
 
 test shadow-link
                              TEST RESULTS
   Port    Maintenance Name  Alt. Name Test No. Result       Error Code
           SHDW-LNK                    318      PASS
 Command Successfully Completed