Справочник Пользователя для Lucent Technologies R5SI
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-653
test shadow-link
8
If the standby SPE is busy with another task, then the following message is
displayed
displayed
Standby SPE busy with another task;
for information use "status system 1"
If the standby SPE is not available when this command is executed, then the
following message is displayed:
following message is displayed:
Standby SPE not available;
for information use "status system 1"
Output
The responses will be displayed on a test-by-test basis with one line of data
displayed for each test result.
displayed for each test result.
For the following output example, assume that the command that was entered
was "test shadow-link"
was "test shadow-link"
Feature Interactions
None.
Port
The port address will always be blank for this command.
Maintenance Name
The maintenance name will always be SHDW-LNK for this
command.
command.
Alt. Name
Not applicable.
Test No
The test number will always be 318 for this command.
Result
The result of the individual test -"PASS," "ABORT," "FAIL,"
"DISABLED,".
"DISABLED,".
Error Code
A system-generated number that tells why the test failed or
aborted. A detailed list of the codes according to "Test No." is
provided for each MO.
aborted. A detailed list of the codes according to "Test No." is
provided for each MO.
test shadow-link
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
SHDW-LNK 318 PASS
SHDW-LNK 318 PASS
Command Successfully Completed