Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Packet Bus Fault Isolation and Correction 
Page 9-3
Tools for Packet Bus Fault Isolation and Correction 
9
The Maintenance/Test Packet Bus port (described in detail later in this chapter) 
can give the remote technician information about the state of the packet bus. 
This information can be obtained via the 
status system
 command and via the 
PKT-BUS test sequence. As described later, the Maintenance/Test circuit pack 
may or may not be present at a customer site, depending on system 
configuration. If a Maintenance/Test circuit pack is not present, one must be 
taken to the customer site.
In a high or critical reliability system, a Processor Interchange may resolve the 
packet bus problem. This operation can be done remotely, and is discussed in 
the 
 section in this chapter.
Tools for Packet Bus Fault Isolation 
and Correction
The following list discusses several tools that are (or may be) required to perform 
Packet Bus Fault Isolation and Correction. The technician should be provided 
with these tools at the customer site:
TN771 Maintenance/Test circuit pack for use in standalone mode, as well 
as the required connectors and cables. (Refer to the 
 section in this chapter.)
Replacement TN771 Maintenance/Test circuit pack may be needed. 
Conditions for requirement, and the relevant implementation steps are 
documented in the 
 section in 
this chapter.
Backplane pin-replacement kit may be required in the procedures 
described in the 
 section of this chapter. If 
the kit is not available, replacement of a carrier may be required.
Packet Bus
Each port network has its own packet bus, and, accordingly, there is one packet 
bus MO in each port network. The packet bus is not duplicated, as is the TDM 
Bus. However, there are several spare leads on the packet bus and, in high and 
critical reliability systems, these spare leads are used to recover from some 
failures on the packet bus.
Packet Bus Usage 
The packet bus carries ISDN-BRI signaling information for ISDN-BRI stations and 
data modules and for ASAI adjunct connections. The TN556 ISDN-BRI circuit 
pack is used for these connections. The SPE interface to the packet bus is the 
TN778 Packet Control (in high and critical reliability systems, there is one TN778 
in each SPE). For systems with multiple port networks, the TN570 Expansion 
Interface is used to pass messages from the packet bus in one port network to