Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-20
ADX8D-BD (AUDIX Circuit Pack) 
10
ADX8D-BD (AUDIX Circuit Pack)
The ADX8D-BD maintenance object represents a TN566/TN2169 DEFINITY 
AUDIX circuit pack (sometimes called Embedded AUDIX) operating in 
digital-port (DP) mode. For circuit pack problems, see “XXX-BD (Common Port 
Circuit Pack)”. Port level problems are covered by ADX8D-PT.
DEFINITY AUDIX
 
consists of two circuit packs that occupy 5 slots on a port 
cabinet. The tests described in this manual apply only to switch-side 
maintenance which tests circuit pack components related to the TDM bus 
interface. The AUDIX system has an extensive maintenance strategy that is 
described in 
DEFINITY AUDIX System Maintenance
, 585-300-110.
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier designation
(A, B, C, D, or E). 
SS is the number of the slot in which the circuit pack resides (01 to 21).
MO Name (in 
Alarm Log)
Alarm Level
Initial Command To Run
1
Full Name of MO
ADX8D-BD
MINOR or 
WARNINGS
test board PCSS sh
AUDIX Circuit Pack