Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-56
ANL-16-L (16-Port Neon Analog Line) 
10
Station Present Test (also called Ringing 
Application Test) (#48)
This test provides a burst of ringing current to the terminal equipment and 
detects that current flows. This test ascertains whether terminal equipment is 
connected to the port.
1
FAIL
This does not indicate a hardware problem. The switchhook audit failed. 
The other updates were not performed because of this failure. This may 
occur when the audit is performed at the same time that the terminal 
equipment goes off-hook. Use the 
status station
 command to determine 
when the port is available for testing.
1. When the port becomes available for testing, retry the command at 
one-minute intervals a maximum of five times.
5
FAIL
This does not indicate a hardware problem. However, there may be an 
internal software error. The message waiting lamp update failed. The 
translation and ringer updates were not performed because of this failure.
7
FAIL
The translation update failed. This does not indicate a hardware problem. 
However, there may be an internal software error. The ringer update was 
not performed because of this failure.
8
FAIL
This does not indicate a hardware problem. However, there may be an 
internal software error. The ringer update failed.
1. Retry the command at one-minute intervals a maximum of five times.
PASS
The software and the port processor have the same status. User-reported 
troubles on this port should be investigated by using other port tests, by 
examining station wiring, or by examining the station.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
list 
config
 command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board long
 command. This should re-establish the 
linkage between the internal ID and the port. If this is not the case, 
dispatch to check to ensure that there is a valid board inserted.
Table 10-23.
TEST #36 Station Status and Translation Audits and Updates Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page