2. Installation
RuggedCom® RuggedPower™
10
RP100 Installation Guide Rev100
2.
-/N = AC NEUTRAL, and is connected to the NEUTRAL terminal of the AC power source.
3.
Ground  must  be  connected  to  the  Safety  Ground  via  a  braided  cable  or  other  appropriate
grounding wire.
4.
Safety Ground should be connected to the power supply ground or equipment ground bus.
2.3. DC Power Supply Wiring and Grounding
+
Figure 2.3. DC Power Supply and Ground Connections
Connect the DC power supply as follows:
1.
+/L = DC (+), and is connected to the positive (+) terminal of the DC power source.
2.
-/N = DC (-), and is connected to the negative (-) terminal of the DC power source.
3.
Ground  must  be  connected  to  the  Safety  Ground  via  a  braided  cable  or  other  appropriate
grounding wire.
4.
Safety Ground should be connected to the power supply ground or equipment ground bus.
Ground  must  be  disconnected  from  Chassis  Ground  during  HIPOT  (Dielectric
strength) testing.
2.4. RJ45 Ports – Signal Description
2.4.1. 10/100 TX Port
10/100Base-TX ports allow connection to standard CAT-5E STP (shielded twisted pair) cable with
RJ45 male connectors. The RJ45 receptacles are directly connected to the chassis ground on the
unit and can accept CAT-5E STP (shielded twisted pair) cables. When shielded cables are used,
care must be taken to ensure that a ground loop is not formed via the shield wire and the RJ45
receptacles at either end. 
 shows the RJ45 port pinout.