MMB Web-UI (Web User Interface) Operations 
 
TABLE 1.74 Display Items and Set Items of [Power Management Setup] Window 
Items 
Description 
Displays number (0~3) to identify the partition. However displays only the 
partitions registered by SB/IOU. 
Partition Name 
Displays the name given to the Partition. 
Power Control Status 
Displays the operating state of power control status of each partition. 
 
Normal:  Normal operating state. Shows that the operating rate 
suppression function for limitation of the electric power consumption is not 
working. 
 
Power Saving:  Shows that the operating rate is being suppressed 
Power Save Control 
Valid/ invalid Power Saving function setting is executed in the partition unit. 
 
Enable 
 
Disable 
 
The setting can be done only when System Power Save Control is Enable and 
gray color is shown when System Power Saving Control is Disable. 
 
Default is Enable 
Power save Grace Period 
Sets shutdown waiting time in Power Save Grace Period Partition unit when the 
Limit threshold is exceeded. 
Specified in the range of 0 ~ 99 minutes. 
 
Shows a valid item when Power Save Control of partition is Enable and shows 
gray color when Disable. 
 
Default is 5 minutes. 
Action reaching Power 
Save 
Executes the operation setting in the partition unit after the Limit threshold 
excess stand-by time. 
 
Continue:  Continues operation for the partition under operation. 
 
Partition Power Off:  Power Off is done for the partition under operation. 
 
Partition Force Power Off:  Force Power Off is done for the partition under 
operation. 
 
Displays a valid item when Power Save Control of partition is Enable and 
displays gray color in case of Disable. 
 
Default is Partition Power Off 
 
TABLE 1.75  [Power Management Setup] Window Buttons 
Buttons 
Description 
Apply 
The setting of the Power Management Setup is changed. 
Cancel 
Returns to the original state without changing the setting of the Power Management Setup. 
 
(1)  Menu Operation 
[Partition] - [Power Management Setup] 
 
(2)  Window Operations 
1. 
Set the items for changing the settings of the Power Management Setup and click the [Apply] button. 
Set the connection. 
 
[Message] 
 
This section describes the messages to be displayed on this window. 
Message Number 
Message 
I_00013 
Setting completed.
 
W_00426 
Invalid values specified.