MMB Web-UI (Web User Interface) Operations 
 
Status 
The state of a physical drive is displayed. 
· 
Operational 
· 
Available 
· 
Failed 
· 
Hot Spare 
· 
Rebuilding 
· 
SMART err 
· 
Not-present 
Vendor 
The vendor of a physical drive is displayed. 
Model 
The model name of a physical drive is displayed. 
Capacity 
The capacity of a physical drive is displayed. 
Logical Drives 
Sensor# 
The sensor number of a logical drive is displayed. 
Status 
The state of a logical drive is displayed. 
RAID Level 
The RAID level of a logical drive is displayed. 
Physical Drives 
assignment 
The slot number of a physical drive that composes a logical drive is displayed. 
Missing drives 
Count 
The number of physical drives missed to compose a logical drive at the RAID level is 
displayed. 
RAID Action Progress 
Drive Type 
The drive type that the RAID action is executed is displayed. 
· 
Physical : Hardware RAID 
· 
Logical   : Software RAID 
Slot#/Sensor# 
Slot# from which the RAID action is executed is shown when Drive Type is Physical, 
and Sensor# from which the RAID action is executed is shown when Drive Type is 
Logical. 
Action 
The RAID action under execution is displayed. 
· 
Rebuilding : It is shown for a physical drive to execute the rebuild of the RAID 
drive. 
· 
MDC Running : It is shown for a logical drive to execute MDC(Make Data 
Consistent). 
Progress 
The progress rate of the RAID action under execution is displayed by the percentage. 
Estimated time 
remaining 
(hh:mm:ss) 
The remaining time that will be expected by the time the RAID action under execution is 
completed is displayed. 
Chipset 
Chipset 
· 
OK 
· 
Warning 
· 
Failed 
TPM 
TPM 
Displays the status of the TPM. 
· 
OK 
· 
Warning 
· 
Failed 
Notes 
When the SB is ‘without TPM mode’, this field is not displayed. 
Remark 
The TPM is not displayed in the SB for China. 
BMC